{"id":72,"date":"2020-07-17T20:16:09","date_gmt":"2020-07-17T20:16:09","guid":{"rendered":"http:\/\/www.misirliogullari.com\/?page_id=72"},"modified":"2020-07-17T20:25:45","modified_gmt":"2020-07-17T20:25:45","slug":"tesisat-kontrolu","status":"publish","type":"page","link":"https:\/\/www.misirliogullari.com\/index.php\/tesisat-kontrolu\/","title":{"rendered":"Tesisat Kontrol\u00fc"},"content":{"rendered":"\n<p><strong>Elektrik Tesisat\u0131 Periyodik Kontrolleri<\/strong>&nbsp;;25.04.2013 tarih ve 28628 say\u0131l\u0131 Resmi Gazetede yay\u0131mlanan&nbsp;<strong>\u201c\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi\u201d<\/strong>&nbsp;kapsam\u0131nda ve bu y\u00f6netmelikte at\u0131fta bulunulan, a\u015fa\u011f\u0131da listelenen ilgili y\u00f6netmeliklere g\u00f6re ger\u00e7ekle\u015ftirilir..<br>*21\/8\/2001 tarihli ve 24500 say\u0131l\u0131 Resm\u00ee Gazete\u2019de Yay\u0131nlanan&nbsp;<strong>\u201cElektrik Tesislerinde Topraklamalar Y\u00f6netmeli\u011fi\u201d<\/strong>.*30\/11\/2000 tarihli ve 24246 say\u0131l\u0131 Resm\u00ee Gazete\u2018de yay\u0131mlanan \u201c<strong>Elektrik Kuvvetli Ak\u0131m Tesisleri Y\u00f6netmeli\u011fi\u201d.<\/strong>*16\/06\/2004 tarihli ve 25494 say\u0131l\u0131 Resm\u00ee Gazete\u2019de yay\u0131mlanan&nbsp;<strong>\u201cElektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi\u201d.<\/strong><br>TS EN 60079 \u2013 TS EN 60439 \u2013 TS EN 61439 \u2013 TS EN 61557 \u2013 TS HD 60364-6 \u2013 TS 5141 EN 12954 \u2013 TS EN 13509 \u2013 TS EN 12817 \u2013 TS EN 12819 \u2013 TS EN 62305 standartlar\u0131<\/p>\n\n\n\n<p>\u0130\u00e7 tesisat \u00f6l\u00e7\u00fcm ve incelemeleri kapsam\u0131nda fabrika, \u00fcretim tesisi, ofis binalar\u0131, hastaneler gibi \u00e7ok say\u0131da farkl\u0131 tipte binan\u0131n elektrik tesisat\u0131n\u0131n t\u00fcm bile\u015fenleri incelenmektedir.&nbsp;<br>\u00d6l\u00e7\u00fcm ve incelemeler kapsam\u0131nda t\u00fcm son t\u00fcketici noktalar\u0131 (\u00fcretim makineleri, \u015febeke ve UPS prizleri) ana da\u011f\u0131t\u0131m panolar\u0131 ve tali da\u011f\u0131t\u0131m panolar\u0131 ile sigortalar, termik manyetik \u015falterler, ka\u00e7ak ak\u0131m r\u00f6leleri ve bunlara ba\u011fl\u0131 kablo tesisatlar\u0131 incelenmektedir.<br><em><strong>\u0130\u00e7 Tesisat \u00d6l\u00e7\u00fcm\u00fcn\u00fcn Getirileri<\/strong><\/em><br>\u0130\u00e7 tesisat \u00f6l\u00e7\u00fcm ve incelemeleri, tesisin elektriksel ekipmanlar\u0131n\u0131n bir r\u00f6ntgeni gibidir. Tesisat i\u00e7erisinde ar\u0131zaya sebep olabilecek zay\u0131f noktalar tespit edilmi\u015f olmaktad\u0131r.<br>Tesis i\u00e7erisinde makinelerin ar\u0131zalanmas\u0131na sebep olabilecek noktalar\u0131n yan\u0131 s\u0131ra, elektrik tesisat\u0131n\u0131n yang\u0131na kar\u015f\u0131 zay\u0131f noktalar\u0131 da tespit edilmektedir.<br>\u00d6l\u00e7\u00fcm ve incelemeler sonucunda \u0130\u015f\u00e7i sa\u011fl\u0131\u011f\u0131 ve i\u015f g\u00fcvenli\u011fi a\u00e7\u0131s\u0131ndan problem yaratabilecek eksiklikler raporlanarak, firmalara i\u015f g\u00fcvenli\u011fi a\u00e7\u0131s\u0131ndan kapsaml\u0131 bir rapor sunulmu\u015f olacakt\u0131r.<br>\u0130\u00e7 tesisat raporu ile tesiste elektrik tesisat\u0131nda revizyon yap\u0131lmak istendi\u011finde ayr\u0131nt\u0131l\u0131 bir ke\u015fif raporu olarak kullan\u0131labilmektedir.<br>Tesiste meydana gelen bir ar\u0131za durumunda t\u00fcm noktalar\u0131n belirtildi\u011fi i\u00e7 tesisat raporu kullan\u0131larak ar\u0131zalara \u00e7ok daha h\u0131zl\u0131 m\u00fcdahale etme imkan\u0131 do\u011fmaktad\u0131r.<br>Tesiste t\u00fcm noktalar\u0131n kontrol\u00fc ile tesis sahibi firmalar, elektriksel periyodik kontrollerde \u0130\u015f\u00e7i Sa\u011fl\u0131\u011f\u0131 ve \u0130\u015f G\u00fcvenli\u011fi kapsam\u0131ndaki t\u00fcm sorumluluklar\u0131 yerine getirmi\u015f olmaktad\u0131rlar.<br><em><strong>\u0130\u00e7 Tesisat Raporunun Kapsam\u0131 Nedir?<\/strong><\/em><br>Tesis b\u00fcnyesinde bulunan,<br>Ana Da\u011f\u0131t\u0131m Panosu ve Tali Panolar<br>Sigorta Kutular\u0131<br>Son t\u00fcketici noktalar\u0131 (\u00dcretim tesislerinde makinelerin, plaza ve ofis binalar\u0131nda elektronik te\u00e7hizat\u0131n ba\u011fl\u0131 oldu\u011fu \u015febeke ve UPS prizleri,.. vb. noktalar ile hastanelerde t\u00fcm medikal cihazlar ve ba\u011fl\u0131 olduklar\u0131 prizler)<br>Jenerat\u00f6r, Kompres\u00f6r, Hidrafor Pompalar\u0131 gibi statik noktalar<br>Paratoner ve Y\u0131ld\u0131r\u0131mdan Korunma tesisleri (Faraday Kafesi t\u00fcm ini\u015f iletkenleri dahil)<br>Mevcut y\u00f6netmelikler dahilinde dikkatle incelenir ve \u00f6l\u00e7\u00fcmler yap\u0131larak raporlan\u0131r. Bu raporlarda tesisteki her bir elektriksel ba\u011flant\u0131 noktas\u0131, sigorta ve \u015faltere ait t\u00fcm bilgiler m\u00fc\u015fterilerimize ula\u015ft\u0131r\u0131lm\u0131\u015f olmaktad\u0131r.<br><em><strong>\u0130\u00e7 Tesisat \u00d6l\u00e7\u00fcm ve \u0130ncelemeleri Hangi Mevzuat Maddelerine ba\u011fl\u0131 olarak yap\u0131lmaktad\u0131r?<\/strong><\/em><br>\u0130\u00e7 tesisat incelemesi kapsam\u0131nda yap\u0131lan \u00f6l\u00e7\u00fcm ve kontroller mevcut y\u00f6netmelik maddeleri ile birlikte a\u015fa\u011f\u0131da s\u0131ralanmaktad\u0131r:<br><br>\u2022 T\u00fcm sigorta, \u015falter, art\u0131k ak\u0131m koruma d\u00fczene\u011fi (ka\u00e7ak ak\u0131m r\u00f6lesi), \u015febeke prizi ve ups prizi gibi elektriksel elemanlar\u0131n tespiti ve numaraland\u0131r\u0131lmas\u0131<br>\u2022 Topraklama \u00f6l\u00e7\u00fcmleri (\u0130\u015f g\u00fcvenli\u011fi t\u00fcz\u00fc\u011f\u00fc madde 270 \u2013 354, Elektrik Tesislerinde Topraklamalar Y\u00f6netmeli\u011fi Madde 7 ve 10)<br>\u2022 \u00c7evrim empedans\u0131 \u00f6l\u00e7\u00fcmleri (Elektrik Tesislerinde Topraklamalar Y\u00f6netmeli\u011fi Madde 10.c.6.2)<br>\u2022 \u0130zolasyon direnci \u00f6l\u00e7\u00fcmleri (Elektrik Tesislerinde Topraklamalar Y\u00f6netmeli\u011fi Madde 10.c.3)<br>\u2022 S\u00fcreklilik testleri&nbsp;<br>\u2022 Art\u0131k ak\u0131m koruma d\u00fczene\u011fi (Ka\u00e7ak Ak\u0131m R\u00f6lesi) testleri (A\u00e7ma ak\u0131m\u0131(mA) ve A\u00e7ma S\u00fcresi(ms) tespiti) (Elektrik Tesislerinde Topraklamalar Y\u00f6netmeli\u011fi Madde 10.c.6.3.i)<br>\u2022 Gerilim d\u00fc\u015f\u00fcm\u00fc \u00f6l\u00e7\u00fcmleri<br>\u2022 Panolarda bulunan kablolar\u0131n ak\u0131m ta\u015f\u0131ma kapasitesinin \u00f6l\u00e7\u00fcm\u00fc ve kontrol\u00fc&nbsp;<br>\u2022 Panolarda iletkenlerin ba\u011flant\u0131 kontrolleri (Elektrik Tesislerinde Topraklamalar Y\u00f6netmeli\u011fi Madde 10.b.1-2)<br>\u2022 Panolar\u0131n, d\u0131\u015far\u0131dan gelebilecek elektriksel olmayan etkilere kar\u015f\u0131 korunmas\u0131n\u0131n kontrol\u00fc (Elektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi Madde 30.c)<br>\u2022 Panolarda, tek hat \u015femas\u0131 ve ayr\u0131nt\u0131l\u0131 a\u00e7\u0131klamalar\u0131n kontrol\u00fc<br>\u2022 Panolarda elektriksel tehlike ve uyar\u0131 i\u015faretlerinin kontrol\u00fc (Kuvvetli Ak\u0131m Tesisleri Y\u00f6netmeli\u011fi Madde 21)<br>\u2022 Panolarda bulunan \u015falter, sigorta ve art\u0131k ak\u0131m koruma d\u00fczene\u011fi gibi ekipmanlar\u0131n etiketlendirilmesinin kontrol\u00fc (Elektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi Madde 51.d)<br>\u2022 Panolarda ve sigorta kutular\u0131nda bulunan kablolar\u0131n mekanik etkilere kar\u015f\u0131 kontrol\u00fc (Elektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi Madde 57.a.1)&nbsp;<br>\u2022 Pano ve sigorta kutular\u0131nda kablolar\u0131n renk kodlamas\u0131n\u0131n uygunlu\u011funun kontrol\u00fc (Elektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi Madde 57 De\u011fi\u015fik F\u0131kra: RG 30\/11\/1995-22479)<br>\u2022 Panolarda bulunan topraklama ve n\u00f6tr baralar\u0131n\u0131n kontrol\u00fc<br>\u2022 Topraklama iletkeninin son t\u00fcketici noktalar\u0131na kesintisiz ta\u015f\u0131nm\u0131\u015f olmas\u0131n\u0131n kontrol\u00fc<br>\u2022 Panolar\u0131n, d\u0131\u015far\u0131dan gelebilecek mekanik etkiler ile s\u0131cakl\u0131k etkilerine kar\u015f\u0131 kontrol\u00fc (Elektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi Madde 51.a)<\/p>\n\n\n\n<p>Rapor \u00d6rne\u011fi;<br>\u0130\u00e7 Tesisat Rapor \u00d6rne\u011fi :\u00a0<em><strong><a rel=\"noreferrer noopener\" href=\"http:\/\/www.mustafafazlioglu.com.tr\/wp-content\/uploads\/2020\/01\/ELEKTRIK-TESISAT-RAPORU.pdf\" target=\"_blank\">i\u00e7 tesisat raporu<\/a><\/strong><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Elektrik Tesisat\u0131 Periyodik Kontrolleri&nbsp;;25.04.2013 tarih ve 28628 say\u0131l\u0131 Resmi Gazetede yay\u0131mlanan&nbsp;\u201c\u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi\u201d&nbsp;kapsam\u0131nda ve bu y\u00f6netmelikte at\u0131fta bulunulan, a\u015fa\u011f\u0131da listelenen&#8230;<\/p>\n","protected":false},"author":1,"featured_media":73,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-72","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/pages\/72"}],"collection":[{"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/comments?post=72"}],"version-history":[{"count":2,"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/pages\/72\/revisions"}],"predecessor-version":[{"id":92,"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/pages\/72\/revisions\/92"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/media\/73"}],"wp:attachment":[{"href":"https:\/\/www.misirliogullari.com\/index.php\/wp-json\/wp\/v2\/media?parent=72"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}